1. Support two-person collaborative operation;
2. The double transfer chamber is independently controlled, and samples can be transferred to the operation chamber at the same time;
3. Single mode/double mode can be switched, and 1 device can be disassembled into 2 independent controls;
4. The operation chamber is equipped with an independent incubator, and the cells are not disturbed by the operation, and there are 6 standard incubators, including 2 20L incubators, 4 10L incubators, with a total volume of 80L, and the incubator is humidified with a water tray, equipped with a hydrophobic membrane, and the humidity can reach 90-95%RH to prevent dehydration of the medium and ensure the optimal culture conditions;
5. Standard color capacitive touch screen, screen size 10.1 inches, real-time monitoring and recording of culture parameters, easy to operate;
6. Accurate parameter control, including real-time monitoring of temperature, gas and humidity, simulating different physiological environments, and supporting multiple models of hypoxia, hyperoxic and intermittent gas control to meet more research needs;
7. One-button parameter control, through the buttons on the touch screen, you can complete the opening and closing of oxygen concentration, carbon dioxide concentration, temperature, humidity, pressure, fan, lighting and other items with one click, and click [one-key stop] on the main interface to turn off all controls;
8. The internal size of the operation compartment: 1944mm×508m×591mm, which can be built into various small equipment;
9. Oxygen control range: 0.1%~99%, accuracy ±0.1%@≤90%, ±0.2%@>90%, support percentage and absolute oxygen partial pressure display in two forms;
10. CO2 control range: 0.1%~30%, accuracy ±0.1%@5%;
11. The temperature control range of the operation chamber: ambient temperature +3°C~45°C, accuracy ±0.1°C;
12. Humidity control range of operation chamber: ambient humidity ~ 85%RH;
13. Positive pressure control system, micro positive pressure environmental protection samples are not polluted;
14. Intermittent gas control: intermittent control of oxygen and carbon dioxide concentration, independent setting of parameters such as oxygen, carbon dioxide, time and cycle times, the number of gradient sections can be set to 10 stages, the number of cycles can be set to limited circulation (1~999 times) and infinite cycles, and the concentration of maintenance section can be set;
15. With the appointment function, you can make an appointment for oxygen, carbon dioxide, temperature, humidity, lighting, ultraviolet lamps and other categories on/off, the appointment duration can be 0-10080 minutes, and the remaining time of the appointment can be displayed in real time;
16. Efficient space filtration, standard HEPA 14 filtration system, ISO Class 3 cleanliness to protect samples from contamination;
17. Large-capacity transfer chamber 27L, gas purging dual mode optional, nitrogen purge time, vacuum replacement times and vacuum degree and other parameters can be set;
18. The linkage mechanism between the inner and outer doors of the transfer warehouse ensures that the inner and outer doors cannot be opened at the same time to ensure safe transmission;
19. It has a bare hand cuff operating system, which can be pumped/inflated through the foot switch or setting interface;
20. The overall ergonomic design, 10° inclined plane, large window transparent panel with bare hands, wide line of sight, flexible and comfortable operation;
21. Large window transparent panel, thickness 20mm, safe and reliable;
22. Standard lift-top front panel for easy transfer of equipment or large volumes of samples to/from the operator compartment or for deep cleaning of the equipment;
23. The operation compartment adopts active sealing, which has better air tightness and is more convenient to use and maintain;
24. LED lighting is standard, and the brightness can be set at 5 levels, which can be adjusted independently according to needs;
25. It is equipped with 6 built-in power sockets as standard, which is convenient for built-in handheld centrifuges, small microscopes and other small instruments, which is convenient and safe to use;
26. The operation chamber is equipped with condensation and humidity reduction function as standard;
27. Built-in ultraviolet lamp is standard, which can disinfect the gas in the operating compartment;
28. The disinfection time of the ultraviolet lamp can be adjusted independently, and the maximum can be set to 10080 minutes;
29. It has the function of one-key calibration of oxygen sensor and timing calibration reminder;
30. With three-level authority control, equipment management is safe and efficient;
31. Curve display, you can view the real-time curve and historical curve of parameters such as oxygen concentration, carbon dioxide concentration, temperature, humidity and operation chamber pressure;
32. Data export function, historical data can be queried and exported independently, and up to 180 days of data can be exported;
33. The log query function allows you to view user operation logs, including operation time, user, and operation content.
34. Historical alarm information query function, you can query the current alarm and historical alarm information, independently select the target time period, view the alarm details during the period, and export the alarm information;
35. The system screen can display the information of the manufacturer and the agent, and if you encounter any questions or failures, you can directly consult through the official channels;
36. Chinese operating system, more in line with the operation and use of Chinese users;
37. It has the function of air source pressure detection, prompts the user to replace the gas cylinder in time to ensure the continuity of the experiment;
38. Safety and alarm function: the instrument will protect and alarm when the control timeout and parameter overtime are exceeded, and the control will be automatically turned off.